| WATER FILM PAINTING CABINS |
![]() |
Our
water film painting cabins are realized using first class materials which
guarantee the efficiency and duration in time. The modular structure is
constructed in zinc-plated bending-pressed sheet. This machine has been
suggested for suction and pigment demolition emitted by spraying made with
synthetic and/o organic and/o waterly solvents. The particolar modular structure,
constructed with zinc-plated bending-pressed sheet panels allows us to realize
a cabin whose size fits well with any enviroment or fully and clearly stated
requirement by the customer. The electric components belong to the IMQ type
and according to the law. All cabins of our production are provided with
Declaration of Conformity, CE brand and constructed in consideration of
the laws in force. The planning, due to researches and experience, classifies
our painting cabins among the most advanced and modern all over Europe |
|
SPECIFICATIONS
|
| VENTILATORE |
| CABIN TYPE | 2 MT | 3 MT | 4 MT | 5 MT | 6 MT |
| INSTALLED ENGINE POWER | CV 1,5 | CV 3 | CV 3 | CV 4 | 2 x 3 CV |
| ABSORBED ENGINE POWER | Kw 1,08 | Kw 2,1 | Kw 2,1 | Kw 2,8 | 2 x 2,1 Kw |
| REVOLUTIONS/MIN | 1.390 | 1.420 | 1.420 | 1.430 | 1.420 |
| ENGINE | 380
V. - B5 50 Hz - IP 55 |
380
V. - B5 50 Hz - IP 55 |
380
V. - B5 50 Hz - IP 55 |
380
V. - B5 50 Hz - IP 55 |
380
V. - B5 50 Hz - IP 55 |
|
PREVALENCE mm. H20 |
Max.
66 Min. 32 |
Max.
81 Min. 38 |
Max.
81 Min. 38 |
Max.
92 Min. 29 |
Max.
81 Min. 38 |
|
AIR CAPACITY Mc/h |
Min..
2.700 Max.. 7.650 |
Min.
3.850 Max. 10.800 |
Min.
3.850 Max. 10.800 |
Min..
5.400 Max. 17.000 |
Min.
7.300 Max. 21.600 |
| NOISINESS | 70 dB (A) | 74 dB (A) | 74 dB (A) | 75 dB (A) | 74 dB (A) |
| PUMP TYPE |
| CABIN TYPE | 2 MT | 3 MT | 4 MT | 5 MT | 6 MT |
| Tipo pompa | CONDOR 120 T | CONDOR 120 T | CONDOR 120 T | CONDOR 200 T | CONDOR 200 T |
| INSTALLED PUMP POWER | CV
1,2 Connection 2" |
CV
1,2 Connection 2" |
CV
1,2 Connection 2" |
CV
2 Connection 3" |
CV
2 Connection 3" |
| PUMP CAPACITY Q= l/m | Min..
0 Max.. 500 |
Min..
0 Max.. 500 |
Min..
0 Max.. 500 |
Min..
100 Max.. 900 |
Min..
100 Max.. 900 |
| PUMP PREVALENCE H = mt | Max.
14 Min. 2 |
Max.
14 Min. 2 |
Max.
14 Min. 2 |
Max.
10 Min. 1 |
Max.
10 Min. 1 |
| PUMP FOR THREE FILMS CABIN | / | CONDOR 200 T | CONDOR 200 T | CONDOR 120 T | CONDOR 120 T |
| PUMP POWER FOR THREE FILMS CABIN | / | CV
2 Connection 3" |
CV
2 Connection 3" |
2
x 1,2 CV Connection 2" |
2
x 1,2 CV Connection 2" |
| PUMP CAPACITY Q= l/m | / | Min..
100 Max.. 900 |
Min..
100 Max.. 900 |
Min..
0 Max.. 500 |
Min..
0 Max.. 500 |
| PUMP
PREVALENCE H = mt |
/ | Max.
10 Min. 1 |
Max.
10 Min. 1 |
Max.
14 Min. 2 |
Max.
14 Min. 2 |
| CABIN TYPE | 2 MT | 3 MT | 4 MT | 5 MT | 6 MT |
| POLYPROPYLENE FILLING BODIES FOR DAMP DESTRUCTION | 0,4 MC | 0,6 MC | 0,8 MC | 1 MC | 1,2 MC |
| MAINTENANCE SYSTEM | Frontal | Frontal | Frontal | Frontal | Frontal |
| TOLERANCE | + / - 5% | + / - 5% | + / - 5% | + / - 5% | + / - 5% |
|
INGOMBRI
|
![]() |
![]() |
| CABIN TYPE | A mm. | B
mm. (Big Basin) |
C
mm. (Little Basin) |
D mm. | E mm. | F mm. | G mm. |
| 2 MT | 2.000 | 2.000 ÷ 2.300 | 1.000 | 300 | 2.120 | 120 | 630 |
| 3 MT | 3.000 | 2.000 ÷ 2.300 | 1.000 | 300 | 2.120 | 120 | 750 |
| 4 MT | 4.000 | 2.000 ÷ 2.300 | 1.000 | 300 | 2.120 | 120 | 750 |
| 5 MT | 5.000 | 2.000 ÷ 2.300 | 1.000 | 300 | 2.120 | 120 | 800 |
| 6 MT | 6.000 | 2.000 ÷ 2.300 | 1.000 | 300 | 2.120 | 120 | 750 |
|
WATER
FILM PAINTING CABINS PRICE-LIST
|
|
A
FILM LITTLE BASIN
|
A FILM BIG BASIN |
THREE
FILMS BIG BASIN
|
|
|
| OPTIONAL |
| SUPPLYING EXCLUSIONS |
| Building works |
| Lifting gears |
| Our fitting feeding: electric power, air, water |
| Above-mentioned fittings permission, included laboratory analysis and papers for the emission in the atmosphere, law 203/88 |
| <<< back |